Wireless Monitoring System
WiSenMeshWAN 6A07/6A08 Vibrating Wire Interface Node
This internally powered sensor node allows integration with upto eight vibrating wire sensors. With wide frequency range (400~6000Hz) and very high accuracy (±0.015%) and precision (±0.002Hz@400Hz or 0.05Hz @6000Hz).
The nodes automatically excite the vibrating wire in the connected devices at required intervals and collate data for the frequency (Hz) and resistance (KΩ).
The node can have multiple channels for sensor input, an integrated temperature sensor and wireless mesh radio transmitter via the external antenna.
Applications: WiSenMeshWAN® VW interface node is Compatible with all different brands & types of high quality Vibrating Wire sensors, therefore it can be applied in all different related monitoring projects. Examples of VW sensors: Strain Gauge; Displacement Transducers; Piezometers; Settlement Sensors; Pressure Cells; Load Cells.
6A07/6A08 Type – WiSenMeshWAN® 1/4-Channel Vibrating Wire Interface Node |
||
Basics |
6A07: 1 x VW Interface Node |
6A08: 4 x VW Interface Node |
Battery Power |
Qty. x 1 (3.6V Lithium primary D-Cell ER34615) |
Qty. x 2 (3.6V Lithium primary D-Cell ER34615) |
Accuracy Stop Voltage |
2.1VDC |
|
Mesh Stop Voltage |
2.1VDC |
|
Battery Connection |
Standard Aluminium Battery Holder |
|
Working Current (DC) |
Max. 60mA (Typ. 48mA) |
|
Local Storage |
Min. 450 Messages during Meshing |
|
L x W x H |
100 x 100 x 60mm |
180 x 140 x 60mm |
Weight |
0.60kg |
1.20kg |
External Sensor Size and Weight |
Depending on the specific VW sensor connected (external cable length ≤ 1.1km) |
|
Cable Gland |
Qty. 1 x EMC-CMA12 for external VW sensor connection |
Qty. 4 x EMC-CMA12 for external VW sensor connections |
Wire Connection |
Spring type wiring terminal |
|
Externally Connected VW Sensor |
||
Sensor Type |
Vibrating Wire Typed |
|
No. of Inputs |
1 Channel |
4 Channels |
Sensor Connection |
VW Type of 5 wires: VW+, VW-, T+, T-, GND. Note: Temperature wires (or a 3kΩ resistor) must be connected to the T+ & T- terminals so VW node can work properly; Ground wire between a node and a sensor must be connected. |
|
Parameter |
Resonant Frequency (Hz) |
|
Range |
400 to 6000Hz |
|
Accuracy |
0.015% at Any Reading |
|
Sensitivity |
0.002Hz@400Hz or 0.05Hz@6000Hz |
|
External Thermistor Sensor |
||
Parameter |
Thermistor Resistor of 3kΩ @25°C |
|
Range |
0.052kΩ to 113.096 kΩ |
|
Accuracy |
0.12kΩ or 2°C |
|
Standard System Parameter |
||
Temperature |
Range: -40 to 85°C, Accuracy: ±1°C, typical 0.5°C; Resolution: 0.1°C |
|
Voltage |
Accuracy: ±0.1V |
|
WSN Interface |
||
Mesh Wireless Interface |
WiSenMeshWAN® Protocol |
|
Re-Calibration Method |
||
Inspection Period |
Every 3 Years by Manufacturer (or inspected by arranged methods) |
|
Industrial Standard |
||
Casing and Painting Materials |
Aluminium-Alloy Die Castings 12 (Epoxy Polyester Powder Coating) |
|
IP Rating |
≥ IP66 |
|
Operating Temperature |
-40 to 85°C |
|
Fire Proof |
Approved |
|
Certificates |
FCC, ACMA |
|
Applications |
||
WiSenMeshWAN® VW interface node is Compatible with all different brands & types of high quality Vibrating Wire sensors, therefore it can be applied in all different related monitoring projects. Examples of VW sensors: Strain Gauge; Displacement Transducers; Piezometers; Settlement Sensors; Pressure Cells; Load Cells. Suggested VW sensor supplier: http://www.soilinstrument.com/ |
||
Installation Guidance |
||
Figure. 1-Channel VW Interface Node Product Photos. Figure. 1-Channel VW Interface Node Brackets.
Figure. VW Sensor Connections (VW+, VW-, T+, T-, GND). Figure. 4 x VW relate Sensor Connection. |
WiSenMeshWAN 6A07/6A08 Vibrating Wire Interface Node
WiSenMeshWAN® Product @ 915, 868, 433MHz Radio Frequency
Casing and Painting Materials: | Aluminium-Alloy Die Castings 12 (Epoxy Polyester Powder Coating) |
IP Rating: | >= IP66 |
Operating Temperature: | -40 to 85°C |
Fire Proof: | Approved |
Certificates: | CE, FCC, ACMA, RoHS, REACH |
-
Vibrating Wire Interface
-
1/4/8 Channel Versions
-
Intelligent node/repeater
-
Battery life up to 15 years
-
1 second to 1 hour variable readings
-
End user configurable
-
Rugged Housing
-
IP66
-
Auto Sweep Range Band Detection to eliminate attenuation noise